Sizing a Compact Odor Adsorber for a Pump Station: A Worked Example

By the NextAir Systems engineering team. Last reviewed October 2026.

Pump stations are the small, awkward odor sources of a sewer network. They sit in residential streets, they are unmanned, they release hydrogen sulfide in bursts, and the people who live nearby know exactly where they are. The equipment to treat them is simple. The sizing is where mistakes creep in.

This example works from the wet well to a finished specification: airflow, bed size, fan power and annual electricity. The method carries over to any enclosed odor source.

The short version

  • A wet well with 400 m³ of headspace ventilated at an assumed 6 air changes an hour gives a flow of 2,400 m³/h, which needs 1.5 m² of bed face area at 0.45 m/s.
  • Fan power for a 1.8 kPa system at 55% efficiency is roughly 2.2 kW at 2,400 m³/h, or about 19,000 kWh a year if it runs continuously.
  • Running continuously is not always necessary. Intermittent extraction timed to pump cycles can cut the energy without raising the odor risk if the controls are designed for it.
  • The wet well is a hazardous location and the electrical equipment has to suit it.[1]

Start with the airspace

Wet wells vary, but assume a headspace of 400 m³ above the working level, which is a well of about 10 m by 8 m with 5 m of airspace. The ventilation rate is set by your design standard. We use 6 air changes an hour to show the arithmetic: 400 × 6 = 2,400 m³/h. That is the flow the adsorber has to treat, and it falls inside the 1,000 to 20,000 CMH range of a single horizontal unit.

If the well can be sealed tighter, or the working volume is smaller, the airflow falls proportionally and so does everything below. This is the same logic as in capture at source: reduce the air before you size the equipment.

From flow to bed and fan

With a design face velocity of 0.45 m/s and a 0.9 m bed, the face area is the flow in m³/s divided by 0.45, the media volume is face area times 0.9, and the fan power is flow times system pressure divided by efficiency. We assume a total system pressure of 1.8 kPa, which includes the bed, ducting and inlet and outlet losses, and a fan efficiency of 55%. These are illustrative assumptions and your design will have its own.

Flow (m³/h)Bed face area (m²)Media volume (m³)Fan power (kW)Electricity per year if continuous (kWh)
1,0000.60.60.97,964
2,4001.51.32.219,113
5,0003.12.84.539,818
10,0006.25.69.179,636

Doubling the flow doubles the bed, the fan power and the energy. This is why a station designed for a 50% higher air change rate than it needs carries that cost for its whole life.

Loading and media life

Worked example. Take the 2,400 m³/h flow at an average of 15 ppm H₂S. At 1.39 mg/m³ per ppm, the load is 15 × 1.39 × 2,400 ÷ 1,000 = 50 g/h, or 1.20 kg a day. The bed holds 1.33 m³ at a 2 second contact time, which is about 667 kg of media at an assumed 500 kg/m³. At an assumed 12% working capacity that absorbs 80 kg of sulfide, a life of about 66 days. The method is explained in the media life worked example.

If that comes out shorter than the interval at which a crew visits, change one of the inputs. Bring the average down by chemical dosing upstream, add bed volume, or lengthen the contact time. A station that needs a media change every two weeks has the wrong adsorber, not the wrong crew.

Controls and monitoring

  • Extraction timing. Run the fan continuously, or in step with the pumps. If the well vents between pump cycles, a continuous low rate is safer than an intermittent high one.
  • Outlet sensor. An H₂S sensor at the outlet is the cheapest way to see breakthrough before a neighbour does.
  • Differential pressure. A gauge across the bed shows when dust or moisture is building up.
  • Access. The unit should be reachable by a vehicle that can lift the media, and the change-out routine should be written down.
  • Telemetry. Many networks already have remote monitoring at pump stations, so adding a sensor channel is cheap.

What to put in the specification

  • The wet well headspace volume and the ventilation rate you design to, with the standard or code that sets it.
  • The H₂S log, including peaks, and any other compounds such as mercaptans or ammonia.
  • The outlet target in ppm or odour units, and where it applies.
  • The electrical classification of the area and the required enclosure ratings.
  • Access for change-out, the route for spent media, and the interval at which the site is visited.
  • Noise limit at the nearest dwelling and any planning constraints on the appearance of the unit.

Noise and appearance

Pump stations are in residential streets, so noise at the property line matters. A small adsorber with a well-chosen fan is quiet, but the fan outlet and any louvres can carry sound. Ask for a sound power figure and check it against the boundary limit using the calculation in our sound power to sound at the fence guide. A screened enclosure is cheap compared with a complaint.

Where this fits with NextAir

NextAir builds horizontal odor control adsorbers from 1,000 CMH upward, with proprietary media in 900 mm bays and options for outlet monitoring. Send the well dimensions, ventilation basis and H₂S log to our odor control adsorber manufacturer team. Background on the technology is in our dry odor control adsorber guide, and wastewater treatment describes the wider network.

Sources

  1. US OSHA. Hydrogen Sulfide: Standards.
  2. US OSHA. Hydrogen Sulfide: Hazards.

Figures and tables on this page are calculated or compiled by NextAir Systems and you are welcome to reuse them with a link back to this article.

Frequently Asked Questions

How do I size an odor adsorber for a pump station?

Work out the airflow from the headspace volume and the ventilation rate, then size the bed for about 2 seconds of contact time at a 0.45 m/s face velocity, and check the media life against your visit interval.

How many air changes does a wet well need?

That is set by the standard or code you design to. The 6 air changes an hour used in this article is an assumption chosen to illustrate the arithmetic.

Should the fan run all the time?

Often yes, at a low rate. Intermittent extraction can save energy, but the controls must prevent odors escaping between cycles.

What fan power does a small odor adsorber need?

For 2,400 m³/h at an assumed 1.8 kPa and 55% efficiency, about 2.2 kW. It scales with flow and with system pressure.

Is a wet well a hazardous area?

OSHA has a policy classifying a wet well as a Class 1, Division 1 location, so electrical equipment and entry procedures need to suit that.

Talk to Our Engineering Team