Odour Units and EN 13725: How to Read an Odour Survey

By the NextAir Systems engineering team. Last reviewed October 2026.

An odour survey arrives as a table of numbers with an unfamiliar unit, ouE/m³, and no obvious way to turn it into equipment. The unit is simple once you see what it measures, and the chain from lab result to treatment design is only three steps long.

Here is how the method works, how to calculate an odour emission rate from a result, and the limits of what the standard covers, so you can ask the right questions of a consultant or a laboratory.

The short version

  • The European odour unit (ouE/m³) is defined so that the concentration at the detection threshold is 1 ouE/m³. A result of 1,000 ouE/m³ means the sample had to be diluted 1,000 times before a panel could just detect it.[1]
  • EN 13725 measures odour concentration by dynamic olfactometry, using a panel of human assessors as the sensor, with a typical range of 10 to 10 million ouE/m³ including pre-dilution.[1]
  • Odour emission rate = odour concentration × volumetric flow. A source at 2,000 ouE/m³ and 10,000 m³/h emits about 5,600 ouE/s.
  • The standard does not measure how neighbours experience odour in ambient air. That is covered by field methods such as EN 16841-1.[1]

What the unit means

Odour is not a single chemical, so there is no meter you can point at it. The European approach is to ask people. A sample of the air is diluted with clean air in steps until a panel can only just tell it from clean air. The dilution factor at that point is the odour concentration. EN 13725 defines the unit so that the concentration at the detection threshold is, by definition, 1 ouE/m³, and expresses everything else as a multiple of it.[1]

The standard specifies dynamic olfactometry with a panel of human assessors acting as the sensor, and gives a typical measurement range of 10 to 10 million ouE/m³ including pre-dilution.[1] It can also measure the mass concentration at the detection threshold of a pure substance, in g/m³, which is how researchers compare, say, hydrogen sulfide with a mercaptan. That is a different job from measuring a mixed industrial odour.

From concentration to emission rate

A concentration tells you how strong the sample is. A design needs how much odour leaves the source every second. The standard notes that determining an odour emission rate also requires measurement of the gas velocity, to obtain the volume flow.[1] The calculation is then:

  • Odour emission rate (ouE/s) = concentration (ouE/m³) × flow (m³/s)
  • Equivalent: concentration × flow (m³/h) ÷ 3,600
Flow (m³/h)Concentration (ouE/m³)Emission rate (ouE/s)Per hour (million ouE)
2,0005002781
5,0001,0001,3895
10,0002,0005,55620
20,0005,00027,778100

The two lowest-concentration rows show why flow matters: a small flow at a high concentration and a large flow at a lower concentration can give a similar emission rate, but they are very different treatment problems. A strong, low-volume source suits a compact adsorber. A weak, high-volume source usually needs capture changes first, which is the argument in capture at the source.

How to read the report

  • Where was the sample taken? A stack, a duct before treatment and a hatch above a tank give very different numbers. Ask for the point, the date and the process condition.
  • What was the flow? Without it, a concentration cannot become an emission rate.
  • Was it a single sample or several? Odours vary with time of day, load and weather. One sample is a snapshot.
  • How was it transported and stored? Samples are analysed in the laboratory, so the report should say how long they waited.
  • Which odorants are driving it? The odour unit tells you how strong the mixture is, not what is in it. Chemical analysis alongside it tells you what to remove.

A worked reading

Worked example. A survey reports 3,000 ouE/m³ at the inlet of an existing treatment unit, with a measured flow of 8,000 m³/h. The emission rate is 3,000 × 8,000 ÷ 3,600 = 6,667 ouE/s. After treatment the outlet is reported at 150 ouE/m³ at the same flow. The outlet rate is 333 ouE/s, so the unit delivers a reduction of 1 − 150 ÷ 3,000 = 95%. Whether 95% is enough depends on the target at the receptor, and the answer from the arithmetic is only as good as the sampling behind both numbers.

What EN 13725 does not do

The standard’s scope is stationary source emissions. It does not measure what a neighbour smells in ambient air. The standard itself points to CEN’s EN 16841-1, a field inspection grid method, for ambient exposure.[1] So an olfactometry result describes the source, and a complaint pattern or a field survey describes the receptor. A complete picture needs both, and an odour target at the fence line has to be translated into a limit at the source using dispersion calculations, which is a specialist job.

Smell and safety are also separate questions, a distinction covered in our guide to hydrogen sulfide limits. A source can be harmless and still produce a large odour emission rate. The next article, the dilution arithmetic, shows what that rate implies for treatment.

Where this fits with NextAir

NextAir’s dry odor control adsorbers are sized from airflow and the compounds present, with the removal target agreed against your survey results. If you hold an olfactometry report, send it with the flow and the process conditions to our odor control adsorber manufacturer team. Our guide to dry odor control adsorbers describes how the technology works, and food processing covers a source where odour is as much about brand as compliance.

Sources

  1. CEN (EN 13725:2022), via EVS. EN 13725:2022 Stationary source emissions: determination of odour concentration by dynamic olfactometry and odour emission rate.
  2. US OSHA. Hydrogen Sulfide: Hazards.

Figures and tables on this page are calculated or compiled by NextAir Systems and you are welcome to reuse them with a link back to this article.

Frequently Asked Questions

What is an odour unit?

The European odour unit (ouE/m³) is based on dilution to the detection threshold. The concentration at the threshold is by definition 1 ouE/m³, and a sample that must be diluted 500 times to reach it measures 500 ouE/m³.

How is odour concentration measured?

By dynamic olfactometry under EN 13725, in which a panel of human assessors smells a sample diluted with clean air in steps until they can just detect it.

How do I calculate an odour emission rate?

Multiply the odour concentration in ouE/m³ by the flow in m³/s, or by the flow in m³/h divided by 3,600. The result is in ouE/s.

Does EN 13725 measure odour at the neighbour's fence?

No. It applies to emissions from stationary sources. Ambient odour is assessed with other methods, such as the field inspection grid method in EN 16841-1.

What range can olfactometry measure?

EN 13725 gives a typical range of 10 to 10 million ouE/m³, including pre-dilution.