How to Choose an Air Purification System Manufacturer: What the Stages, Ratings and UV-C Claims Mean
NextAir Systems, Faridabad, India. Last reviewed October 2026.
A centralized air purification system is sold as a list of stages, and the list is easy to make look impressive. The quality is in the details behind each line: what rating the filter actually has, how fast the air moves through it, how long it is exposed to ultraviolet light, and whether you can reach each part to service it.
These checks apply to any manufacturer. Where we need figures, we use the design of our own NAP range, built on the standard 610 x 610 mm filter module.
At a glance
- Our standard train is a MERV 8 pre-filter, a MERV 13-14 fine filter and a UV-C chamber, with a gas-phase module and HEPA as options.
- Our UV-C chamber gives about 0.45 seconds of residence time at design velocity, so the lamp output must deliver the dose in under half a second. Ask for the dose and the organism it is specified to.
- Face velocity is a design choice: we target about 1.9 m/s through the filters, which balances pressure drop against filter life.
- Insist on ISO 16890 classes if you care about fine particles, because MERV numbers do not report the same thing.
Check 1: is the stage order sensible?
Air should meet the cheapest, coarsest stage first and the most expensive stage last. Our NAP units follow this order: an inlet transition with damper, a MERV 8 pleated pre-filter, a MERV 13-14 extended-media fine filter, a UV-C germicidal chamber, an optional gas-phase module, and a direct-drive centrifugal fan section. The pre-filter takes the coarse dust so the fine filter lasts longer. A quotation with the stages in a different order, or with the UV-C lamps ahead of the filters, deserves a question.
Check 2: what do the filter ratings mean?
The National Air Filtration Association gives a rough guide: ISO Coarse corresponds to about MERV 1 to 8 and ePM1 to about MERV 13 to 16, though the two standards do not report the same thing.[1] That puts a MERV 8 pre-filter at the top of the coarse group and a MERV 13-14 fine filter in the ePM1 range. Where a PM-fraction specification is required, ISO 16890 (ePM1, ePM2.5, ePM10) rated filtration is an option on our units. Our guide to MERV, ISO 16890 and EN 1822 explains how to read the ratings, and HEPA, at 99.97% at 0.3 microns, is available as an upgrade to or in addition to the fine filter.
Check 3: what is the face velocity?
A bank of filters has a face area, and the airflow divided by it gives the velocity. Lower velocity means lower pressure drop and longer filter life. We target about 1.9 m/s. The table shows how many 610 x 610 mm modules that needs for several airflows, calculated from the module area of 0.372 m². It illustrates the method and is not a model table.
| Airflow (CMH) | Modules at exactly 1.9 m/s | Modules (rounded up) | Face velocity with that many (m/s) |
|---|---|---|---|
| 2,000 | 0.79 | 1 | 1.49 |
| 5,000 | 1.96 | 2 | 1.87 |
| 10,000 | 3.93 | 4 | 1.87 |
| 15,000 | 5.89 | 6 | 1.87 |
| 20,000 | 7.86 | 8 | 1.87 |
Ask every supplier for the face velocity, the module count and the pressure drop. The energy effect of that choice is worked in filter face area, velocity and energy.
Check 4: what UV-C dose does it deliver?
Ultraviolet dose is irradiance multiplied by exposure time. With 0.45 seconds of residence, the lamps have to be powerful. The table shows the average irradiance needed to deliver some example doses in that time, calculated as dose divided by time.
| Target dose (mJ/cm²) | Average irradiance needed over 0.45 s (mW/cm²) |
|---|---|
| 5 | 11.1 |
| 10 | 22.2 |
| 20 | 44.4 |
| 40 | 88.9 |
The doses are illustrations, since the right figure depends on the organism and the standard you are working to. Our lamp output and count are specified to the target organism. Ask any manufacturer for the dose, the organism, the lamp count, the lamp life and how lamp hours are tracked. A claim of germicidal UV with none of these is marketing. Also remember that UV-C inactivates microorganisms in the air; it does not remove particles or gases.
Check 5: can you reach every stage?
Standard NAP construction is a galvanized steel frame with powder-coated exterior panels, and hinged or removable access panels at every stage for filter change-out and lamp service. A local panel shows the pressure differential across each filter stage and tracks run hours and lamp hours. Stainless steel housing is an option for coastal or corrosive sites. Ask to see the access arrangement, because filters get changed only as often as they are easy to reach. The economics of when to change them are in filter change-out economics.
Check 6: how does it scale?
Our single units run from NAP-0500 to NAP-20000, 500 to 20,000 CMH, in one horizontal housing format that keeps the same length at every size. Above 20,000 CMH there are two routes: a bank of units, which suits several zones or sites that cannot tolerate an outage, or a sectionalised single casing built as two or more shippable sections, tested at the factory and bolted and sealed on site. Ask any supplier how they would deliver your airflow and what happens to the system if one part fails.
Checks 7 to 10: gases, evidence, lead time and terms
- Gases. Particle filters do not remove odours or VOCs. Where gas-phase control is the main duty, dedicated adsorbers carry a higher loading than the optional module in a purification unit.
- Evidence. Ask for the filter class test reports, the lamp data sheet and a pressure-drop table at clean and final condition.
- Lead time. Our minimum is 30 days, with larger systems taking longer.
- Terms. Warranty, spares for two years, and the Incoterm, in writing.
What to send us for a quotation
- Airflow, or the volume and occupancy of the space and the ventilation standard you follow
- The contaminants of concern: dust, fine particles, microorganisms, odours or VOCs
- The filtration standard required: MERV, ISO 16890 class or HEPA
- Outdoor air quality at the site, if you have measurements
- Electrical supply, available space and whether the site is coastal or corrosive
- Whether you need a single unit, a bank or a sectionalised casing
Send these to us through our contact page and we will propose the stages, the module count and the pressure drop. Our guide to centralized air purification explains the technology, and the NAP range lists the models. Typical settings are covered on the healthcare and pharmaceutical pages, and a unit often sits with an air handling unit or alongside a dry VOC adsorber for gases.
Sources
- National Air Filtration Association (NAFA). ISO 16890 user guide: understanding ePM and ISO Coarse.
Frequently Asked Questions
How do I choose an air purification system manufacturer?
Check the stage order, the filter ratings on a recognised standard, the face velocity, the UV-C dose and residence time, access for servicing, and how the system scales. Then compare lead time and terms.
What is the UV-C residence time in NextAir units?
About 0.45 seconds at design velocity. Lamp output and count are specified to the target organism.
What filter classes do NextAir units use?
A MERV 8 pre-filter and a MERV 13-14 fine filter as standard, with HEPA at 99.97% at 0.3 microns and ISO 16890 rated filtration as options.
What airflow range do your units cover?
NAP-0500 to NAP-20000, which is 500 to 20,000 CMH in a single unit. Above that, banks or a sectionalised casing are used.
Does UV-C remove odours or particles?
No. It inactivates microorganisms. Particles are removed by the filters, and odours and VOCs need a gas-phase stage.
Talk to Our Engineering Team
Call +91-9311805618 or use our contact form for a facility-specific recommendation.