Banana Ripening Room Ethylene Control Supplier: Using Ethylene on Purpose, and Removing It Elsewhere
NextAir Systems, Faridabad, India. Last reviewed October 2026.
Ripening is the one place in the fruit trade where ethylene is a tool and not a problem. A ripening room is dosed with ethylene to bring bananas to colour together. The same gas, in the holding room next door or in the truck, ruins the fruit you are trying to keep green. So the work for an ethylene scrubber around bananas is at the edges: clearing the ripening room when the cycle ends, and keeping the other rooms clean.
NextAir builds ethylene scrubbers from 1,200 to 30,000 CMH for tropical fruit, where ethylene is used deliberately for ripening and must be controlled elsewhere. This page shows how fast a scrubber clears a ripening room and where else it helps.
At a glance
- Bananas are in the moderate ethylene production class, 1 to 10 µL/kg·h, and ethylene at 0.02% (200 ppm) in air may accelerate ripening 4 to 10 times.[1]
- For a 300 m³ ripening room with a 90%-efficient scrubber, reducing ethylene from 100 ppm to 1 ppm takes about 18 minutes with a 5,000 CMH unit and about 5 minutes with 20,000 CMH.
- A scrubber does not belong in the room during the dosing phase, which is where you want the ethylene. It belongs at the clearance step and in the holding rooms.
- The sizing starts from the crop, the volume and how fast you want to clear, not from the room alone.
Two different jobs
In a ripening room, the cycle has a dosing phase and a ventilation phase. During dosing the room is closed and ethylene is deliberately held at a level that triggers ripening. At the end the gas must go, and the fruit moves on. The faster the room clears, the faster it can be reloaded, which is a throughput question. In holding rooms and during transit, the aim is the opposite: keep ethylene near zero so that green fruit stays green. Those two jobs need the same equipment used differently, and a supplier should ask which you mean.
How fast can a scrubber clear a room?
With air recirculating through the scrubber, the ethylene concentration falls exponentially. The time constant is the room volume divided by the airflow times the per-pass efficiency. To go from 100 ppm to 1 ppm needs the natural logarithm of 100, about 4.6 time constants. The table calculates the time for a 300 m³ room at four scrubber airflows with a 90% per-pass efficiency, which is an illustrative value.
| Scrubber airflow (CMH) | Effective air changes per hour (at 90%) | Minutes from 100 ppm to 1 ppm |
|---|---|---|
| 2,000 | 6.0 | 46 |
| 5,000 | 15.0 | 18 |
| 10,000 | 30.0 | 9 |
| 20,000 | 60.0 | 5 |
A 5,000 CMH unit clears the room in about twenty minutes, and a 2,000 CMH unit in about three quarters of an hour. Ventilating with outside air is the usual alternative, but in a warm climate that brings in heat and humidity and takes longer. The 100 ppm start point is an assumption for illustration, since your dose is set by your process. What matters is that clearance time is a design choice, and the scrubber airflow is how you set it. The calculation behind the general sizing is in how to size ethylene removal.
Where else it earns its place
- Holding and cold rooms for green fruit awaiting ripening, where any ethylene leaks from the ripening rooms or from other produce shortens the green life.
- Dispatch and loading areas, where ripened fruit and green fruit meet.
- Mixed stores where bananas share space with ethylene-sensitive items, as in mixed loads and ethylene.
- Long transit holds, where a unit controls the atmosphere of a larger space.
Sizing and layout
Standard single units run from 1,200 to 30,000 CMH, horizontal or vertical. A horizontal vessel suits limited headroom, and a vertical vessel saves floor area where there is height to use. For a large ripening complex, several scrubbers in parallel let you clear rooms in sequence, and let you change media in one unit while the others keep working. Scrubber media is replaced against the cumulative ethylene load over the whole period, which for a ripening operation depends on how many cycles you run, and our quotation asks for the crop, the volume and the throughput. The method is in planning ethylene media change-out.
The clearance time has a commercial meaning. If each ripening cycle is held up for hours while the room is vented, that is a room that is not earning. If a scrubber cuts the clearance from several hours to twenty minutes, the room can be turned around at a pace the loading schedule sets, and the plant can run more cycles a week. Put your cycle length and your target turnaround in the enquiry, and we will size the scrubber to hit them, not just to clear the room eventually.
What to ask a supplier
- How is the scrubber used in a room that also needs ethylene dosed into it?
- What clearance time does the design give for my room volume, and from what starting concentration?
- How is ethylene measured so I know when the room is clear?
- What happens to the media when the room is dosed repeatedly?
- How do the connections follow my plant room layout?
For the general supplier checklist, see how to choose an ethylene scrubber manufacturer, and for our sector page, bananas and tropical fruit.
What to send us for a quotation
- Ripening room volume, number of rooms and the cycle length
- Dosing level and how quickly you need the room cleared
- Whether you also need the scrubber on holding rooms or loading areas
- Throughput: how many cycles a week
- Voltage, frequency, plant-room space and headroom
- Horizontal or vertical preference
Send these to us through our contact page and we will recommend an airflow and a layout. See the ethylene scrubber range, the guide to ethylene scrubbers and our notes for Kenya and Mumbai. Ripening rooms need temperature and humidity control too, so see our air handling units.
Sources
- TIS-GDV (German insurers’ transport information service). Allelopathy: ethylene production rates and sensitivity of fruit and vegetables.
Frequently Asked Questions
Do you supply ethylene control for banana ripening?
Yes. We build scrubbers for tropical fruit, where ethylene is used deliberately for ripening and must be controlled elsewhere, from 1,200 to 30,000 CMH.
Does the scrubber run during ripening?
Not while you want ethylene in the room. It is used to clear the room at the end of the cycle, and in holding rooms and other areas where ethylene must be kept low.
How fast can a scrubber clear a ripening room?
For a 300 m³ room at 90% per-pass efficiency, about 20 minutes with 5,000 CMH, from 100 ppm to 1 ppm, as an illustration.
What ethylene level accelerates ripening?
TIS-GDV reports that 0.02% (200 ppm) in air may accelerate ripening 4 to 10 times.
What do you need to quote?
The crop, room volumes, cycle times, how fast you need clearance, and the plant-room space.
Talk to Our Engineering Team
Call +91-9311805618 or use our contact form for a facility-specific recommendation.
Contact Us