Controlled Atmosphere Store Ethylene Scrubber Supplier: Apples and Pears in Sealed Rooms
NextAir Systems, Faridabad, India. Last reviewed October 2026.
A controlled atmosphere room is sealed on purpose. Oxygen is held low and carbon dioxide high to slow the fruit down. That helps with ethylene, because low oxygen suppresses its production, but it also means the ethylene the fruit does make has nowhere to go. A scrubber is how it leaves.
NextAir builds ethylene scrubbers from 1,200 to 30,000 CMH, horizontal or vertical, for apple and pear CA storage, which is the highest-producing crop group we serve. This page works through how much the CA conditions reduce the duty, and what that means for the size of the scrubber.
At a glance
- Apples sit in the very high ethylene production class, above 100 µL/kg·h at 20 °C, and pears in the high class.[1]
- Low oxygen and elevated carbon dioxide inhibit ethylene biosynthesis in apples, according to UC Davis research.[2]
- For 500 t of apples at the 100 µL/kg·h class floor, a 1 ppm target with a 90% per-pass scrubber needs about 55,556 CMH, which is 2 units of 30,000 CMH, if no reduction from cold and CA is assumed. At a tenth of that rate it needs 5,556 CMH.
- Our media replacement is planned against the cumulative ethylene load for the whole season, so the crop and the storage duration are part of every quotation.
A sealed room has no other exit
Ventilation removes ethylene from an ordinary cold store by dilution. A CA room cannot ventilate, because its atmosphere is the point. The ethylene the fruit produces therefore accumulates until something removes it, and the scrubber is that something. It works continuously while the room is sealed, drawing room air through proprietary media that oxidizes ethylene and returning it. Without it, the concentration in a loaded room rises steadily, as the room arithmetic in ethylene production by crop shows.
How much do cold and low oxygen reduce the duty?
The classic production rates are quoted at 20 °C. A CA room runs cold and lean in oxygen, and both reduce production. University of Florida material notes that ethylene production peaks near 25 °C,[3] and UC Davis research shows that low oxygen and elevated carbon dioxide inhibit ethylene biosynthesis in apples.[2] We do not have a published figure for how much a particular room reduces the rate, so the table treats the reduction as a variable: the rate at 20 °C, and fractions of it.
| Production relative to the 20 °C class floor | Ethylene from 500 t (µL/h) | Airflow for a 1 ppm target at 90% per pass (CMH) | Units of 30,000 CMH |
|---|---|---|---|
| No reduction (20 °C figure) | 50,000,000 | 55,556 | 2 |
| Halved | 25,000,000 | 27,778 | 1 |
| Quartered | 12,500,000 | 13,889 | 1 |
| Tenth | 5,000,000 | 5,556 | 1 |
The table says what to expect from the design process: the size of the scrubber depends strongly on an assumption that is easy to get wrong. If the real production is a tenth of the textbook figure, one unit may do. If it is the full figure, you need a bank. A supplier who asks you for the rate at your storage conditions, and for your target, is doing the right sum. The worked method is in how to size ethylene removal and the temperature effect in temperature, atmosphere and ethylene production.
Horizontal or vertical in a CA complex
CA rooms are often tall and tightly packed, with plant rooms squeezed alongside. A horizontal vessel suits spaces with limited headroom, and a vertical vessel saves floor area where there is height to use. We choose between them from your floor area, headroom and airflow, and build both. Large complexes use several scrubbers in parallel, and a bank also lets you change media in one unit while the others keep scrubbing, which matters when rooms cannot be opened.
Media and the season
A long storage season loads the media with ethylene week after week, and the replacement interval has to match the cumulative load, not the room’s size. A highly productive variety needs meaningfully more capacity than a lower-ethylene crop in the same volume. The planning method is in planning ethylene media change-out.
A practical point about measurement: the only way to know what a CA room really produces is to measure it. A few readings with an ethylene analyser after loading, repeated through the season, replace the assumed rate with the real one, and they tell you whether the scrubber is holding the target. Put an analyser in the specification if you can, because a scrubber you cannot verify is a scrubber you have to take on trust.
Checks before you order
- What ethylene production rate did the supplier assume, and at what temperature and oxygen level?
- Which target concentration does the design hold, and why?
- How is the media replaced without opening a sealed room more than necessary?
- Where does the scrubber’s fan draw from and return to, so the room air mixes well?
- What footprint and headroom do the horizontal and vertical options need?
For the general supplier checklist, see how to choose an ethylene scrubber manufacturer, and our apple and pear CA storage page for the sector.
What to send us for a quotation
- Crop, variety and tonnage per room, and the storage duration
- Room volume, temperature and the CA regime (oxygen and carbon dioxide levels)
- The target ethylene concentration and the sensitivity of the crop
- Number of rooms and whether they share plant
- Voltage, frequency, plant-room space and headroom
- Horizontal or vertical preference, and whether a bank is wanted
Send these to us through our contact page and we will size the scrubber and the media for your season. See the ethylene scrubber range and our guide to ethylene scrubbers. Our regional notes for South Africa and India cover local storage practice, and CA rooms often need humidity control outside the sealed rooms.
Sources
- TIS-GDV (German insurers’ transport information service). Allelopathy: ethylene production rates and sensitivity of fruit and vegetables.
- J. R. Gorny and A. A. Kader, UC Davis, 1997. Low Oxygen and Elevated Carbon Dioxide Atmospheres Inhibit Ethylene Biosynthesis in Preclimacteric and Climacteric Apple Fruit.
- University of Florida IFAS (postharvest). Ethylene Treatments (presentation).
Frequently Asked Questions
Do you supply ethylene scrubbers for CA stores?
Yes. We build scrubbers from 1,200 to 30,000 CMH, horizontal or vertical, with multi-bank systems above that, for apple and pear CA storage among other duties.
Why does a CA room need a scrubber?
Because the room is sealed, so ventilation cannot remove ethylene. The scrubber removes it continuously while the room stays closed.
Does low oxygen reduce the scrubber size needed?
It reduces ethylene production, so the duty is lighter than the 20 °C figure suggests, but by how much depends on the room, so size on your storage conditions.
How is media life planned?
Against the cumulative ethylene load for the whole storage season, so crop and duration are part of every quotation.
Can I change media without opening rooms?
A bank lets you change media in one unit while the others keep scrubbing. Ask how the arrangement works for your rooms.
Talk to Our Engineering Team
Call +91-9311805618 or use our contact form for a facility-specific recommendation.
Contact Us