Hygienic Air Handling Unit Manufacturer: Washdown, Cascades and Cleanability for Food and Pharma

NextAir Systems, Faridabad, India. Last reviewed October 2026.

A hygienic air handling unit is not a standard unit with a better finish. It is a unit designed so that it can be cleaned, so that it cannot become the source of contamination it is supposed to prevent, and so that it can hold a pressure cascade between rooms of different cleanliness. Those three requirements decide the construction, and they are worth writing down before the quotation.

NextAir builds industrial air handling units from 1,000 to 30,000 CMH for food and beverage plants, where hygienic design suits washdown and clean-to-dirty pressure cascades, and for pharmaceutical GMP clean areas. This page sets out what to specify, and works through the air a pressure cascade needs.

At a glance

  • Food and beverage plants need hygienic design suited to washdown and clean-to-dirty pressure cascades, and pharmaceutical facilities need GMP clean areas with cleanroom classification and humidity held under control.
  • We fabricate the casings, frames and sections in our own factory, so section lengths and connection positions can follow your plant room.
  • A pressure cascade is held by air flowing through gaps. A 0.01 m² gap at a 10 Pa difference passes about 96 m³/h, so the supply and extract must be balanced with that in mind.
  • Specify the hygienic requirements in writing, because the details of construction are agreed per project against your standard.

What hygienic design means in an AHU

Three questions decide it. Can every surface that the air touches be reached and cleaned? Can water drain completely, so nothing stands in the unit? Can the unit be washed down, or is it protected from the washdown in the room around it? A food plant that washes floors and walls with water and chemicals needs a unit that survives it. A pharmaceutical plant needs a unit that does not shed particles or hold moisture. The details, such as casing finish, internal surfaces, drain pans and door seals, are agreed per project against your standard and your auditor, and we do not claim a fixed hygienic specification here. State your requirement in the enquiry and we will confirm what we can build.

  • Drainage. The coil section produces water, as quantified in how much water an AHU makes. Ask how the pan drains, how the trap is sized, and how the pan is accessed for cleaning.
  • Access. Doors, sections and lengths that let a person clean every stage, which our fabrication of casings and sections to the plant room helps.
  • Filtration. The filter classes and their sealing, with HEPA or fine filters as the process needs, and a way to check the pressure drop across each.
  • Humidity control. A cooling coil reaches a limit, and where the target is lower a desiccant stage is the answer. See our dehumidifiers.

The pressure cascade

In a food plant, air should flow from clean areas to dirty ones, and never the reverse. In a pharmaceutical plant, cleaner rooms are held at higher pressure than their neighbours. Either way, the AHU supplies more air than the room extracts, and the surplus escapes through the gaps around doors, hatches and penetrations. The pressure difference you need is set by your standard, and the air that must be supplied to hold it is set by the size of the gaps.

The table calculates the leakage through a gap using the orifice equation with a discharge coefficient of 0.65, for four gap areas and four pressure differences. It is a physical calculation and an illustration of scale, since real gaps are irregular.

Leakage area (m²)At 5 Pa (m³/h)At 10 Pa (m³/h)At 15 Pa (m³/h)At 20 Pa (m³/h)
0.00534485868
0.0106896117135
0.020135191234270
0.050338478585675

Worked example. A suite of rooms with an effective leakage area of 0.05 m² held at 15 Pa above its surroundings needs about 585 m³/h of surplus supply air, just to hold the pressure. In a suite with a poor seal and 0.02 m² of extra gap, the AHU has to supply another 234 m³/h. The unit is sized to the airflow, not to the gaps, so tight construction in the building pays twice: smaller equipment and a more stable cascade.

Sizing and range

Our AHUs run from 1,000 to 30,000 CMH in a single unit, with multi-unit arrangements above that and custom-engineered projects beyond 200,000 CMH. For a pharmaceutical production room of around 5,000 CMH, or a hospital department at 7,500 CMH, a single unit is typical. Where continuity matters, a bank gives redundancy. The coil is sized to your region’s peak wet-bulb conditions, as in why enthalpy, not dry-bulb, sizes the coil, and the fan to the full system’s static pressure, as in AHU fan power.

What to write into the specification

  1. The standard your plant or auditor works to, and the areas it applies to.
  2. Washdown: whether the unit is washed internally, or only protected from the washdown outside.
  3. Drain pan slope, trap and cleaning access.
  4. Filter classes, their leak-test requirement and the pressure monitoring.
  5. Pressure cascade: the differentials between rooms and how the unit will be controlled to hold them.
  6. Humidity and temperature targets, with tolerance, and the strategy for holding them.

To compare suppliers, use how to choose an air handling unit manufacturer, and for cleanroom classes see cleanroom air handling units.

What to send us for a quotation

  • The standard or auditor you must satisfy, and the zones it covers
  • Airflow per zone, and the sensible and latent loads
  • The pressure cascade differentials and the room layout
  • Washdown arrangements in the area around the unit
  • Temperature and humidity targets with tolerance, and the design weather
  • Filter classes and any leak-test requirement

Send these to us through our contact page and we will confirm what we can build to your hygienic requirements. See the AHU range, our guide to industrial air handling units, and our pages for food and beverage and pharmaceutical plants. A hygienic AHU often works with an air purification system.

Types and variants we build

Frequently Asked Questions

Do you make hygienic air handling units for food plants?

We build industrial AHUs from 1,000 to 30,000 CMH for food and beverage plants, where hygienic design suits washdown and clean-to-dirty pressure cascades. The detailed construction is agreed per project against your standard.

What is a pressure cascade?

A set of pressure differences between rooms that keeps air flowing from cleaner areas to less clean ones, held by supplying more air than is extracted.

How much air does a pressure cascade need?

It depends on the leakage area. A 0.01 m² gap at a 10 Pa difference passes about 96 m³/h, so tight construction reduces the surplus air needed.

Can the AHU control humidity as well as temperature?

A cooling coil can, to a limit. Where the target is lower than condensation can reach, a desiccant stage is added.

Do you build pharmaceutical GMP air handling units?

Yes. We build AHUs for GMP clean areas, with cleanroom classification and humidity held under control, to your specification.