Packhouse and Cold Room Ethylene Scrubber Manufacturer: From Room Volume to Unit Size

NextAir Systems, Faridabad, India. Last reviewed October 2026.

A packhouse is a place where fruit and flowers wait: after harvest, before packing, before the reefer arrives. The rooms are not sealed like a CA store, they are opened and closed all day, and the produce changes from one week to the next. For ethylene control that means a scrubber sized for the room and the pace, not for one crop.

NextAir builds ethylene scrubbers for export packhouses and cut flowers, where arrival quality decides the sale, and for mixed produce distribution. This page shows how a room volume becomes an airflow and a unit, and what to check.

At a glance

  • Scrubber airflow comes from the room volume and the number of air passes per hour needed to keep ethylene below your crop’s sensitivity threshold. A 2,400 m³ room cycled twice an hour needs 4,800 CMH.
  • Our single units run from 1,200 to 30,000 CMH; a 5,000 m³ room at 2 passes an hour needs 10,000 CMH.
  • Packhouses open and close constantly, so ethylene returns after every opening, and sizing for recovery time matters as much as for steady state.
  • Cut flowers and mixed produce are the sensitive end of the business, where arrival quality decides the sale.

Open rooms behave differently

In a sealed CA store the scrubber works against a steady production. In a packhouse cold room, the doors open, warm air and fresh produce come in, and ethylene from outside and from the product itself builds up. The scrubber has to keep the room’s air clean in spite of that, and bring it back quickly after each disturbance. That favours a unit sized with margin on airflow, so the room turns over often.

From room volume to airflow

The airflow is the room volume times the number of passes of room air through the scrubber per hour. The right number of passes depends on the crop’s sensitivity and the production in the room, and we set it with you; the table shows the airflow for three illustrative pass rates and the standard size of ours that covers each, calculated from our published size range. A 2,400 m³ room at two passes an hour needs 4,800 CMH.

Room volume (m³)1 pass per hour: CMH (unit)2 passes per hour: CMH (unit)4 passes per hour: CMH (unit)
600600 (1,200)1,200 (1,200)2,400 (3,500)
1,2001,200 (1,200)2,400 (3,500)4,800 (5,000)
2,4002,400 (3,500)4,800 (5,000)9,600 (10,000)
5,0005,000 (5,000)10,000 (10,000)20,000 (20,000)
10,00010,000 (10,000)20,000 (20,000)40,000 (bank above 30,000)

A small cold room is one unit. A 10,000 m³ facility at four passes an hour needs more than one scrubber, which is when a bank pays for itself: several units can serve different rooms, and a unit can be taken out for media change while the others run. The relationship between the airflow and the concentration you can hold is in how to size ethylene removal.

Mixed produce and sensitive crops

Packhouses rarely handle one crop. A high ethylene producer next to a sensitive product is the classic problem, and the target for the sensitive crop sets the airflow. Separate rooms are the simplest remedy, and the next best is a scrubber on the shared air. See which produce should not share a room for the logic. Cut flowers are a case where arrival quality decides the sale, and we cover them on our export packhouse and cut flowers page.

Think about how the room is used across the day. A packhouse cold room that is loaded in the morning and emptied by evening has a very different ethylene profile from one that holds product for a week. The first needs fast recovery after each door opening, which argues for more passes per hour. The second needs steady removal against continuous production, which argues for sizing from the crop. Say which pattern applies, because the same room volume can need quite different airflows depending on it.

It also pays to think about where the scrubber draws and returns air. Placing the intake away from the door and the return across the stacked product lets the air sweep the room instead of short-circuiting in one corner. A good layout gets more from a given airflow than a bigger unit in a poor position, and it costs nothing at the design stage. Ask the supplier to show the airflow pattern on a plan of your room before you accept the position.

Horizontal or vertical

A horizontal vessel suits spaces with limited headroom, and a vertical vessel saves floor area where there is height to use. Packhouses are often built around pallet flow, with little spare floor, so a vertical unit is common where the roof is high, and a horizontal one where plant sits in a low service space. We choose from your floor area, headroom and airflow, and connection positions follow your plant room because vessels, frames and fittings are fabricated in our factory.

What to ask

  1. What airflow and how many passes per hour does the design assume for my room and crop?
  2. How quickly does the room recover after the doors have been open?
  3. What does the media cost per season at my throughput?
  4. Can I extend the plant as the packhouse grows?
  5. How is the scrubber monitored, and how will I know when the media is spent?

For temperature and atmosphere effects see temperature, atmosphere and ethylene production, for the loss arithmetic postharvest losses, and for the supplier checklist how to choose an ethylene scrubber manufacturer.

What to send us for a quotation

  • Room volumes and number of rooms
  • Crops handled, tonnage and storage duration
  • The most sensitive product and its tolerance
  • Door openings and throughput through the day
  • Voltage, frequency, plant-room space and headroom
  • Horizontal or vertical preference, and growth plans

Send these to us through our contact page and we will recommend an airflow, a unit or a bank. See the ethylene scrubber range, our guide to ethylene scrubbers and the mixed produce distribution page. Our regional notes for Kenya and the UAE cover local practice, and packhouses also need evaporative cooling in dry climates.

Types and variants we build

Frequently Asked Questions

Do you make ethylene scrubbers for packhouses?

Yes. We build scrubbers from 1,200 to 30,000 CMH for export packhouses, cut flowers and mixed produce distribution.

How do I size a scrubber for a cold room?

Multiply the room volume by the passes of room air per hour your crop needs. A 2,400 m³ room cycled twice an hour needs 4,800 CMH.

Do I need more than one scrubber?

For large facilities, several scrubbers in parallel also let you change media in one unit while the others keep scrubbing.

Do cut flowers need ethylene control?

Arrival quality decides the sale for export flowers, which is why the packhouse and cut flower duty is a listed application for our scrubbers.

How long does the media last?

Replacement is planned against the cumulative ethylene load for the whole season, so the crop and the duration are part of the quotation.

Talk to Our Engineering Team

Call +91-9311805618 or use our contact form for a facility-specific recommendation.

Contact Us